Knowledge Management System Of Guangzhou Institute of Energy Conversion, CAS
Study on borehole temperature distribution when the well-kick and the well-leakage occurs simultaneously during geothermal well drilling | |
Zhang, Zheng1; Wang, Xin1; Xiong, Youming1; Peng, Geng6; Wang, Guorong1,3,4,5; Lu, Jingsheng2; Zhong, Lin4,5; Wang, Jingpeng1,7; Yan, Zhiyin8; Wei, Ruihua9 | |
2022-09-01 | |
发表期刊 | GEOTHERMICS |
ISSN | 0375-6505 |
卷号 | 104页码:14 |
通讯作者 | Zhang, Zheng(zhangzhengswpu@163.com) |
摘要 | When the well-leakage or the well-kick occurs during drilling geothermal wells, the borehole temperature is redistributed. It causes the rheology and density of the mud to change, which in turn affects the borehole pressure control, borehole stability and cementing quality. In order to understand the distribution law of borehole temperature under complex working conditions in geothermal well drilling, this paper establishes a borehole temperature distribution model when well-leakage and well-kick occur simultaneously. The borehole temperature distribution law when well-leakage and well-kick occur simultaneously is obtained. When both the well-kick and the well-leakage exist in the drilling process, the temperature of the borehole and the formation fluctuates near the location where the well-kick and well-leakage occurs. Under the ordinary cycle condition, the highest temperature of annular drilling fluid is located at 5325 m; When the well-leakage occurs at the bot-tomhole and the well-kick occurs at a specific location in the borehole, the highest temperature of annular drilling fluid is at 5250 m; When the well-kick takes place at the bottomhole and the well-leakage occurs at a specific location in the borehole, the highest temperature of annular drilling fluid at 5286 m place. Compared with the ordinary cycle condition, when the well-leakage occurs at the bottom of the well and the well-kick occurs at a specific location in the borehole, the bottomhole mud temperature decreases after the same cycle time. And the temperature of the mud and the formations increases significantly near and above the position where the well-kick takes place. When the well-kick takes place at the bottom of the well, and the well-leakage occurs at a specific location in the borehole, compared with the ordinary cycle condition, the temperature of the bottom hole mud increases after the same cycle time and the mud temperature increases rather than decreases at the well-leakage location. Compared with other situations, it is found that when the well-kick occurs at the bottomhole, it has a more significant impact on the temperature distribution of the entire borehole. |
关键词 | Drilling Well-kick Well-leakage Well temperature |
DOI | 10.1016/j.geothermics.2022.102441 |
关键词[WOS] | SHUT-IN ; CIRCULATION |
收录类别 | SCI |
语种 | 英语 |
资助项目 | National Key Research and Develop-ment Program of China[2018YFC0310201] ; National Key Research and Develop-ment Program of China[2019YFC0312305] ; Natural Science Foundation of China[52004261] ; Natural Science Foundation of China[52174009] ; Guangdong Major project of Basic and Applied Basic Research[2020B0301030003] ; Science and Technology Planning Project of Guangdong Province[2021A0505030053] |
WOS研究方向 | Energy & Fuels ; Geology |
项目资助者 | National Key Research and Develop-ment Program of China ; Natural Science Foundation of China ; Guangdong Major project of Basic and Applied Basic Research ; Science and Technology Planning Project of Guangdong Province |
WOS类目 | Energy & Fuels ; Geosciences, Multidisciplinary |
WOS记录号 | WOS:000805870800002 |
出版者 | PERGAMON-ELSEVIER SCIENCE LTD |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.giec.ac.cn/handle/344007/36739 |
专题 | 中国科学院广州能源研究所 |
通讯作者 | Zhang, Zheng |
作者单位 | 1.Southwest Petr Univ, State Key Lab Oil & Gas Reservoir Geol & Exploitat, Chengdu 610500, Sichuan, Peoples R China 2.Chinese Acad Sci, Guangzhou Inst Energy Convers, Key Lab Gas Hydrate, Guangzhou 510640, Peoples R China 3.Southwest Petr Univ, Energy Equipment Res Inst, Chengdu 610500, Peoples R China 4.Southwest Petr Univ, Sch Mechatron Engn, Chengdu 610500, Peoples R China 5.Southern Marine Sci & Engn Guangdong Lab, Zhanjiang 524000, Peoples R China 6.Petrochina Southwest Oil & Gas Field Co, Engn Technol Res Inst, Chengdu 610031, Sichuan, Peoples R China 7.Xinjiang Oil Field Co, Engn & Technol Res Inst, Karamay 834000, Peoples R China 8.PetroChina Southwest Oil & Gasfield Co, Nat Gas Purificat Plant Gen, Chongqing 400021, Peoples R China 9.Xinjiang Oilfield Co, Explorat Div, Karamay 834000, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Zheng,Wang, Xin,Xiong, Youming,et al. Study on borehole temperature distribution when the well-kick and the well-leakage occurs simultaneously during geothermal well drilling[J]. GEOTHERMICS,2022,104:14. |
APA | Zhang, Zheng.,Wang, Xin.,Xiong, Youming.,Peng, Geng.,Wang, Guorong.,...&Wei, Ruihua.(2022).Study on borehole temperature distribution when the well-kick and the well-leakage occurs simultaneously during geothermal well drilling.GEOTHERMICS,104,14. |
MLA | Zhang, Zheng,et al."Study on borehole temperature distribution when the well-kick and the well-leakage occurs simultaneously during geothermal well drilling".GEOTHERMICS 104(2022):14. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。