GIEC OpenIR
Comparative analysis of conventional and low-GWP refrigerants with ionic liquid used for compression-assisted absorption cooling cycles
Wu, Wei1; Leung, Michael1; Ding, Zhixiong1; Huang, Hongyu2; Bai, Yu2; Deng, Lisheng2
2020-05-25
发表期刊APPLIED THERMAL ENGINEERING
ISSN1359-4311
卷号172页码:15
通讯作者Wu, Wei(weiwu53@cityu.edu.hk) ; Bai, Yu(baiyu@ms.giec.ac.cn)
摘要To address the problems of conventional absorption technologies, various working pairs consisting of low-global-warming-potential hydrofluorocarbons/hydrofluoroolefins and ionic liquid were numerically investigated for two compression-assisted absorption cooling cycles driven by heat sources at lower temperatures. The property prediction model and thermodynamic performance model were established and verified. The performance improvements were evaluated and the compression ratio was optimized. With the compression-assisted absorption cycle, the coefficient of performance (COP) was enhanced from 0.191-0.463 to 0.366-0.670, while the minimum generation temperature was reduced by about 20 degrees C, reaching 45 degrees C. For both basic and compression-assisted absorption cycles, difluoromethane yielded the highest COP, followed by fluoroethane and 1,1-difluoroethane with slightly lower COPs; 2,3,3,3-tetrafluoropropene performed the worst in most conditions; 1,1,1,2-tetrafluoroethane performed worse than trans-1,3,3,3-tetrafluoropropene using the basic cycle but outperformed trans-1,3,3,3-tetrafluoropropene using the compression-assisted absorption cycle. The thermal COP varies similarly to but higher than the COP, while the mechanical COPs are much higher for all the working pairs, reaching 11-14 (R152a showing the highest) with a CR of 1.5. The mechanical COP decreases dramatically with the compression ratio. For the low-pressure compression-assisted absorption cycle with a generation temperature of 70 degrees C, the optimal compression ratios were 1.9-3.4 with the maximum COPs of 0.546-0.663 and were 1.3-2.2 with the maximum exergy COPs of 0.192-0.289. The low-pressure compression-assisted absorption cycle was better than the high-pressure compression-assisted absorption cycle due to the higher cycle efficiency and lower compressor discharge temperature. This study provides suggestions on the selection of compression-assisted absorption cycles, working pairs and optimal parameters for renewable/waste cooling.
关键词Renewable cooling Waste cooling Low global warming potential Novel working pair Ionic liquid Compression-assisted absorption cycle
DOI10.1016/j.applthermaleng.2020.115145
关键词[WOS]THERMODYNAMIC ANALYSIS ; HEAT-PUMP ; PERFORMANCE SIMULATION ; SYSTEM ; EQUILIBRIUM ; WATER ; TRANS-1,3,3,3-TETRAFLUOROPROPENE ; INTEGRATION ; ABSORBENTS ; RECOVERY
收录类别SCI
语种英语
资助项目Research Grants Council of Hong Kong[CityU 21201119] ; Guangdong Basic and Applied Basic Research Foundation[2019A1515011177]
WOS研究方向Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics
项目资助者Research Grants Council of Hong Kong ; Guangdong Basic and Applied Basic Research Foundation
WOS类目Thermodynamics ; Energy & Fuels ; Engineering, Mechanical ; Mechanics
WOS记录号WOS:000525326500004
出版者PERGAMON-ELSEVIER SCIENCE LTD
引用统计
被引频次:44[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.giec.ac.cn/handle/344007/27053
专题中国科学院广州能源研究所
通讯作者Wu, Wei; Bai, Yu
作者单位1.City Univ Hong Kong, Sch Energy & Environm, Hong Kong, Peoples R China
2.Chinese Acad Sci, Guangzhou Inst Energy Convers, Urban Rural Mine Integrated Technol Res Team, Guangzhou, Peoples R China
推荐引用方式
GB/T 7714
Wu, Wei,Leung, Michael,Ding, Zhixiong,et al. Comparative analysis of conventional and low-GWP refrigerants with ionic liquid used for compression-assisted absorption cooling cycles[J]. APPLIED THERMAL ENGINEERING,2020,172:15.
APA Wu, Wei,Leung, Michael,Ding, Zhixiong,Huang, Hongyu,Bai, Yu,&Deng, Lisheng.(2020).Comparative analysis of conventional and low-GWP refrigerants with ionic liquid used for compression-assisted absorption cooling cycles.APPLIED THERMAL ENGINEERING,172,15.
MLA Wu, Wei,et al."Comparative analysis of conventional and low-GWP refrigerants with ionic liquid used for compression-assisted absorption cooling cycles".APPLIED THERMAL ENGINEERING 172(2020):15.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wu, Wei]的文章
[Leung, Michael]的文章
[Ding, Zhixiong]的文章
百度学术
百度学术中相似的文章
[Wu, Wei]的文章
[Leung, Michael]的文章
[Ding, Zhixiong]的文章
必应学术
必应学术中相似的文章
[Wu, Wei]的文章
[Leung, Michael]的文章
[Ding, Zhixiong]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。