摘要 | A water-to-water high temperature heat pump was studied experimentally. The performance of the system was characterized by refrigerant compositions, compressor RPM and water temperature change. For the experimental conditions of the inlet water temperature of evaporator of 40 degreesC and the inlet and outlet water temperatures of the condenser of 70 and 80 degreesC, respectively, the experiment shows that the coefficient of performance is maximum when the molar component of R22 is about 75%. It is shown that the maximum pressure of the system is under 2.5 MPa after taking R22/R141b as working fluids, even though the highest cooling water temperatures is about 80 degreesC. (C) 2002 Elsevier Science Ltd. All rights reserved. |
文章类型 | Article |
关键词 | Mixtures Heat Pump Non-azeotropic Refrigerants |
WOS标题词 | Science & Technology ; Physical Sciences ; Technology |
研究领域[WOS] | Thermodynamics ; Energy & Fuels ; Mechanics ; Physics |
收录类别 | SCI |
语种 | 英语 |
WOS类目 | Thermodynamics ; Energy & Fuels ; Mechanics ; Physics, Nuclear |
WOS记录号 | WOS:000176208000009 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.giec.ac.cn/handle/344007/10441 |
专题 | 中国科学院广州能源研究所 |
作者单位 | 1.Shanghai Jiao Tong Univ, Sch Power & Energy Engn, Inst Refrigerat & Cryogen, Shanghai 200030, Peoples R China 2.CAS, Guangzhou Inst Energy Convers, Guangzhou 510070, Peoples R China 3.Guangdong Univ Technol, Guangzhou 510640, Peoples R China |
推荐引用方式 GB/T 7714 | Li, TX,Guo, KH,Wang, RZ. High temperature hot water heat pump with non-azeotropic refrigerant mixture HCFC-22/HCFC-141b[J]. ENERGY CONVERSION AND MANAGEMENT,2002,43(15):2033-2040. |
APA | Li, TX,Guo, KH,&Wang, RZ.(2002).High temperature hot water heat pump with non-azeotropic refrigerant mixture HCFC-22/HCFC-141b.ENERGY CONVERSION AND MANAGEMENT,43(15),2033-2040. |
MLA | Li, TX,et al."High temperature hot water heat pump with non-azeotropic refrigerant mixture HCFC-22/HCFC-141b".ENERGY CONVERSION AND MANAGEMENT 43.15(2002):2033-2040. |
条目包含的文件 | 条目无相关文件。 |
个性服务 |
推荐该条目 |
保存到收藏夹 |
查看访问统计 |
导出为Endnote文件 |
谷歌学术 |
谷歌学术中相似的文章 |
[Li, TX]的文章 |
[Guo, KH]的文章 |
[Wang, RZ]的文章 |
百度学术 |
百度学术中相似的文章 |
[Li, TX]的文章 |
[Guo, KH]的文章 |
[Wang, RZ]的文章 |
必应学术 |
必应学术中相似的文章 |
[Li, TX]的文章 |
[Guo, KH]的文章 |
[Wang, RZ]的文章 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论